Your search for "STWA1SEH"
Cable length: What is the maximum length of the connection cable?
STWA1S; STWA1SH; STWA1SEH; STWA2SH; STWA1FH
Electronic-current transformers are practical switches. The possible length of the connection cable solely depends on the external circuit.
Cross-section, what is the max. cable cross-section that can be put through?
STWA1S; STWA1SH; STWA1SEH; STWA2SH; STWA1FH
Electronic-current transformers have an inner diameter of 11 mm. Insulated switching wires and stranded wires up to approx. 35 ø nominal cross-section and UL-approved stranded wires up to AWG 4 can be inserted through.
Connecting SWA1S to STW-Relay?
STWA1S
The STWA1S electronic current transformer is not designed for connection to STW relays. It has a residual current of 0.6 mA, which means that the input on the STW would always detect a running machine.
Alternatively, the STWA1SEH current transformer can be used.
Alternative STWA1SEH
You can find an overview of all questions here.