STW161M
Bus module for controlling sliders in extraction systems
Product description
Bus module for controlling sliders in extraction systems
Technical Data
Rated supply
Rated supply voltage Us
AC/DC 24-240 V
Tolerance
DC 20 - 30 V
Power consumption
< 0,5 W
relay outputs (12, 14)
switching voltage
DC 24 V
switching current
max 0,5 A
Rated operating current
DC -13 Ie = 0,5 A Ue = 24 V
Inputs I1, Y3
Connectable converters
STWA1(H), potential-free contact, Current-Sensor Type S1
Overload with STWA1(H)
max. 100 A continuous, max. 300 A 10s
Input Y3
internal resistance
approx. 38 kOhm
switching threshold
ON > 17 V, OUT < 8 V
permissible ambient temperature
-20°C…+55°C
Shaking safety EN 60068-2-6
2...13,2 Hz +/- 1 mm 13,2...100 Hz 1 g
2...25 Hz +/- 1,6 mm 25...150 Hz 5 g
Housing
Dimensions (w x h x d) mm
94 x 130 x 57 mm
Cable connection solid
1 x 0,34-1,5 mm2 / AWG 22-14
Finely stranded with end sleeve
1 x 0,1-1 mm2 / AWG 27-16
Stripping length/torgue
8,5 Nm
Attachment
Screw
Protection housing/terminals
IP 54/ IP 20
Weight
approx. 310 g