Universal Digital Panel meter MINIPAN 350V
Universal Digital Panelmeter, 4 digits, display -1999...+9999, for DIN-rail-mount
Part number
Product description
With its 4 digit, 14 mm high display, Digital Panel meters of MINIPAN 350 V- series allow the accurate display of different values in the range -1999 ... +9999.
Only 3 designs cover the measuring of DC voltage and current, AC voltage and current and temperature with Pt 100- sensors (RTD). The display can be easily programmed by the customer (e.g. input 0-10 V --> display 0-350.0 ms or AC 0-1 A ---> 0- 400.0 A
With the built-in universal power supply AC/DC 24-240 V it is especially versatile.
Inputs DC-Meter:
- Measuring of current with external shunt max. 300 mV
- 1 A for direct measuring of current
- 0/4-20 mA for standardsignals
- 0-10 V for standard-signals
- 100/500 V switchable
Inputs AC-Meter:
- 500 V
- 50 V
- 10 V
- Measuring of current with external shunt max.150 mV
- 1 A for direct measuring of current or with external transformer
Measuring of Temperature Pt 100 (RTD):
- Pt 100 in 2- or 3-wire connection
- Measuring Range -199,9 ... +850,0 °C
- Resolution 0,1 °C
- Display in °C or °F
Easy programming with 3 buttons:
- Display (scaling, decimal-point)
- Display of MIN- and MAX-values
- Delay for display at unstable signals
- Code-lock against manipulation of settings
- Terminals pluggable
- Face-Plate 36 x 72 mm
Technical data
Power Supply
Rated supply voltage Us
AC/DC 24-240 V
Tolerance DC
DC 20 - 297 V (0,85 x 24 V...1,35 x 220 V)
Tolerance AC
AC 20 - 264 V (0,85 x 24 V...1,1 x 240 V)
Power consumption
< 3 VA
Frequency
48...62 Hz
Measuring Inputs
insulated from supply-voltage
(connect 1 input only)
DC-Meter
± 300 mV / 120 kΩ / max. ±2,5 V
Measuring range / resistance of input / overload capacity
± 10.00 V / 1 MΩ / max. ±50 V
+ 500.0 V / -199.9 V / 3 MΩ / max. ±600 V
+ 100.0 V / -100.0 V / 3 MΩ / max. ±600 V
+ 20.00 mA / -19.99 mA/ Shunt 15 Ω/ max. ±100 mA
± 1.00 A / Shunt 150 mΩ / max. ±2 A
AC-Meter
150 mV / 900 Ω / max. 2,5 V
Measuring range / resistance of input / overload capacity
150 mV / 900 Ω / max. 2,5 V
10.00 V / 100 kΩ / max. 50 V
50.0 V / 1 MΩ / max. 60 V
500.0 V / 3 MΩ / max. 600 V
1.00 A / Shunt 150 mΩ / max. 2 A
Measuring time AC/DC
< 400 ms + delay of display
Pt 100- Meter
- 199,9 ... + 850,0 °C (= -328 ... +1563 °F)
Sensor-connection
Pt 100, 2- or 3-wire
Wire-resistance 3-wire
max. 3 x 50 Ω
Measuring time temperature
< 400 ms + delay of display
Accuracy
Resolution / Accuracy (of full measuring range)
+9999 / -1999
DC voltage and current
± 0,1 % ± 1 Digit
AC voltage and current
± 0,5 % ± 1 Digit
Temperature factor
± 0,02 % / Kelvin
Accuracy Pt 100- Meter
± 0,3 % vom Messwert ± 0,5 K
Temperature factor
± 0,03 °C / K
Housing
Housing
Design V2, switchgear mounting
Dimensions (width x height x depth)
35 x 90 x 58 mm
Mounting height
55 mm
Wire connection, one wire
each 1 x 0,5…1,5 mm2
Stranded wire with insulated ferrules
1 x 0,14…1,0 mm2
Protection class housing / Protection class terminal
IP 30/IP 20
Weight
approx. 120 g
Certificates